HP 3PAR CRC errors and Invalid transmission word in correlation with Brocade SAN switches
The advantage of HP 3PAR is hidden in monitoring mechanism. One of them is especially useful in case we do not have any special monitoring within our SAN. Thanks to that, we have opportunity to detect possible issue, before it will affect substantially our environment.
Intermittent CRC Errors Detected
Let’s take a look how HP 3PAR can present such an information to us. First example comes from HP 3PAR Service Processor Onsite Customer Care (SPOCC).
Event type: evt_host_port_crc_errors ID: 30003 Component: Port 3:1:3 Short Dsc: Host Port 3:1:3 experienced over 50 CRC errors (50) in 24 hours Event String: Host Port 3:1:3 experienced over 50 CRC errors (50) in 24 hours ... Event String: Port 3:1:3 Degraded (Intermittent CRC Errors Detected {0x2})
Same thing can be checked on HP 3PAR system itself. Just look at the event log.
3PAR-cluster cli% shoeventlog -oneline -startt 1/1/16 2016-01-01 12:33:18 GMT 2 Minor FC LESB Error sw_port:2:3:2 FC LESB Error Port ID [2:3:2]-Counters: (Invalid transmission word) (Invalid CRC) -ALPAs: 140700 2016-01-01 12:44:19 GMT 2 Minor FC LESB Error sw_port:3:1:3 FC LESB Error Port ID [3:1:3]-Counters: (Invalid transmission word)-ALPAs: 140700